Manual Jog Parameters - Lenze i950 Commissioning Manual

Servo inverters
Hide thumbs Also See for i950:
Table of Contents

Advertisement

Additional functions

Manual jog parameters

Address
Name / setting range / [default setting]
0x2550:008
Brake resistor: Warning threshold
50.0 ... [90.0] ... 150.0 %
0x2550:010
Brake resistor: Response to warning
0 No response
1 Fault > CiA402
2 Warning
0x2550:011
Brake resistor: Response to error
0 No response
1 Fault > CiA402
2 Warning
18.2
Manual jog parameters
Parameter
Address
Name / setting range / [default setting]
0x2836:001
Manual control mode: Current setpoint
0 ... [30] ... 200 %
0x2836:002
Manual control mode: Frequency
-1000.0 ... [0.0] ... 1000.0 Hz
0x2836:003
Manual control mode: Ramp time (current)
0 ... [0] ... 1000 ms
0x2836:004
Manual control mode: Ramp time (frequency)
0 ... [500] ... 10000 ms
0x2836:005
Manual control mode: Time monitoring (frequency)
0 ... [2500] ... 100000 ms
0x2836:006
Manual control mode: Current controller gain
0.00 ... [20.00] ... 750.00 V/A
0x2836:007
Manual control mode: Current controller reset time
0.01 ... [20.00] ... 2000.00 ms
362
Info
Warning threshold for brake resistor monitoring.
• If the utilisation shown in reaches the threshold set, the response
selected in
0x2550:010
is effected.
• The warning is reset with a hysteresis of 20 %.
Selection of the response that is executed when the warning threshold
for brake resistor monitoring is reached.
Selection of the response to be executed when the error threshold for
brake resistor monitoring is reached.
Associated error code:
• 65282 | 0xFF02 - Brake resistor: overload fault
Info
Setting of the current setpoint value for manual control.
• 100 % ≡ Rated current ()
Setting of the frequency for manual control.
Setting of the period of time during which the current setpoint value is
achieved from zero onwards.
Setting of the period of time during which the frequency is achieved
from zero onwards.
The frequency ramp only starts up when the current ramp has reached
the value configured in
0x2836:001
Setting of the time period for time monitoring.
• The manual control features a time monitoring function which is cou-
pled to a write access to
0x2836:002
• If no write access to
0x2836:002
set here, the frequency is moved to zero via the parameterised ramp.
When the 0 Hz have been reached, the inverter changes to the error
status and is inhibited. After acknowledging the error, the CiA402
state machine must be switched from "Switch-on inhibited" back to
the "Operation enabled" state before proceeding with manual con-
trol.
Setting of the current controller gain.
Setting of the current controller reset time.
(Current setpoint).
(Frequency).
takes place within the time period