Appendix; Parameter Attribute List - Lenze i950 Commissioning Manual

Servo inverters
Hide thumbs Also See for i950:
Table of Contents

Advertisement

Appendix

21
Appendix
21.1

Parameter attribute list

The parameter attribute list in particular contains some information required for reading and
writing parameters via network.
The parameter attribute list contains all parameters of the inverter.
The parameter attribute list is sorted by addresses (index:subindex) in ascending order.
How to read the parameter attribute list:
Column
Meaning
Address
Address of the parameter in the object directory. Format: Index:Subindex
Designation
Parameter name
Default setting
Default setting of the parameter
Data type
Data type of the parameter:
I8
I16
I32
I64
U8
U16
U32
U64
STRING[xx]
OCTET[xx]
IDX
Factor
Factor for data transmission via network, depending on the number of decimal positions:
1
10
100
1000
10000
A
Attributes (combinations of several attributes also possible):
C
E
H
I
C
O
P
X
M
Mapping:
r
t
rt
-
Parameter attribute list (short overview of all parameter indexes)
Address
Designation
0x1000
Device type
0x1001
EtherCAT error register
0x1008
Manufacturer device name
0x1009
Manufacturer hardware version
0x100A
Manufacturer software version
0x1018:001
Identity object : Vendor ID
0x1018:002
Identity object : Product ID
* Default setting depending on the size.
438
INTEGER_8
1 byte, with sign
INTEGER_16
2 bytes with sign
INTEGER_32
4 bytes with sign
INTEGER_64
8 bytes with sign
UNSIGNED_8
1 byte without sign
UNSIGNED_16
2 bytes without sign
UNSIGNED_32
4 bytes without sign
UNSIGNED_64
8 bytes without sign
VISIBLE_STRING ASCII string (with character length xx)
OCTET_STRING
OCTET string (with xx bytes)
4 bytes without sign. Is used specially for addressing parameters.
No decimal positions
1 decimal position
2 decimal positions
3 decimal positions
4 decimal positions
Setting can only be changed if the inverter is inhibited.
Value is displayed as IP address.
Value is displayed in hexadecimal form.
Parameter is not displayed.
Parameter is not displayed.
Parameter can be recorded with the oscilloscope function.
Setting is saved in the memory module.
Parameter is not displayed in the engineering tools.
Receive mapping permissible.
Transmit mapping permissible.
Receive and transmit mapping permissible.
Mapping not permissible.
Default setting
- (Read only)
- (Read only)
- (Read only)
- (Read only)
- (Read only)
- (Read only)
- (Read only)
Data type
Factor
A
M
U32
1
X
U8
1
X
STRING[50]
X
STRING[50]
X
STRING[50]
X
U32
1
X
U32
X

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents