Diagnostics; Led Status Displays; Information On The Network - Lenze i950 Commissioning Manual

Servo inverters
Hide thumbs Also See for i950:
Table of Contents

Advertisement

16.4.5

Diagnostics

For diagnostic purposes, the system bus interfaces X246 and X247 provide LED status displays
and diagnostic parameters for the EtherCAT system bus.
The diagnostic parameters are divided according to the interface role (master or slave) set in
0x2371:009.
In the »EASY Starter«, the diagnostic parameters can be accessed in the "Diagnostics" tab via
the "Network diagnostics" button:
LED status display
Notes on the EtherCAT connection status and the data transfer can be obtained via the LED
displays "RUN" and "L/A" at the RJ45 sockets.
16.4.5.1

LED status displays

LED status display
Notes on the EtherCAT connection status and the data transfer can be obtained via the LED
displays "RUN" and "L/A" at the RJ45 sockets.
16.4.5.2

Information on the network

The following parameters show information on the network.
Parameter
Address
Name / setting range / [default setting]
0x2378
Network status
• Read only
1 Initialisation
2 Pre-Operational
3 Bootstrap
4 Safe-Operational
8 Operational
0x2379
Network error
• Read only
0x5851:001
EtherCAT master diagnosis: EtherCAT master state
• Read only
0 Unknown
1 Init
2 Pre-Operational
3 Bootstrap
4 Safe-Operational
8 Operational
0x5851:002
EtherCAT master diagnosis: EtherCAT master state
summary
• Read only
Bit 0 Master OK
Bit 4 Init
Bit 5 Pre-Operational
Bit 6 Safe-Operational
Bit 7 Operational
Bit 8 Slaves in requested state
Bit 9 Master in requested state
Bit 10 Bus scan match
Bit 12 DC enabled
Bit 13 DC in sync
Bit 14 DC busy
Bit 16 Link up
Configuring the network
Info
Display of the active network status.
Display of the active network error.
Display of the EtherCAT master state.
Display of the EtherCAT master state overview.
EtherCAT system bus
Diagnostics
349

Hide quick links:

Advertisement

Table of Contents
loading