Not Ready To Switch On - Lenze i950 Commissioning Manual

Servo inverters
Hide thumbs Also See for i950:
Table of Contents

Advertisement

Configuring the network
Device profile CiA 402
Device states
16.1.6.1

Not ready to switch on

This is the device state of the inverter directly after switching on the supply voltage.
In this device status, the device is initialised.
Communication is not possible yet.
The inverter cannot be parameterised yet and no device commands can be carried out yet.
The motor brake, if available, is closed.
Operation is inhibited.
1
From all states
2
Power section inhibited (pulse inhibit)
3
Power section enabled
Bit pattern in the CiA 402 status word (0x6041)
Bit 15 ... 8
Bit 7
Reserved
Warning
(specific)
active
X
X
X = state is not relevant
302
Mains on
Not ready
to switch on
Switch-on inhibited
Ready to switch on
Switched on
Bit 6
Bit 5
Operation
Quick stop
DC bus ready
inhibited
active
for operation
0
X
Fault reaction
active
Fault
Quick stop active
Operation enabled
Bit 4
Bit 3
Bit 2
Fault active
Operation
enabled
X
0
Bit 1
Bit 0
Switched on
Ready to
switch on
0
0
0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents