Configuring the "Electronic Gearbox" TA
Master value sources
Virtual master
7.3.3.1

Simulation of the virtual master

The technology interface is operated manually via the following parameters:
Simulation of control signals virtual master
Simulation of status signals
Bit 0 of the Simulation of control signals virtual master parameter activates manual opera-
tion of the technology function. All control words are set to manual operation.
Bit 0
The setpoint velocity can be switched over to system bus/fieldbus operation via bit 1 of the
Simulation of control signals virtual master.
Bit 0 of the Simulation of status signals parameter activates the interface simulation. All sta-
tus words are switched over to manual operation.
0x50 :001:Bit 0
45
Fieldbus/System bus
Control word 00
Control word 02
Fig. 43: Basic signal flow
Parameter
Address
Name / setting range / [default setting]
0x5045:001
Simulation of control signals virtual master
0x00 ... [0x00] ... 0xFF
Bit 0 Enable control signal simulation
Bit 1 Activate simulation of control word 1
Bit 2 Activate simulation of control word 2
Bit 3 Activate simulation of control word 3
Bit 4 Activate simulation of control word 4
Bit 5 Activate simulation of control word 5
Bit 6 Activate simulation of control word 6
Bit 7 Activate simulation of control word 7
0x5045:101
Simulation of status signals
0x00 ... [0x00] ... 0xFF
Bit 0
110
40x5045:001
40x5045:101
40x5045:001
40x5045:101
Technology application/Main Technology
0x50 :010
45
0x50 :001:Bit 1
45
0x50 :011
45
40x5045:001
Bit 0
0x50 : 1:Bit 0
45 10
0x50 : 1
Virtual
0x50 :
Master
0x50 :
0x50 :
0x50 :
0x50 :
Info
TRUE: Simulation of control word is activated.
FALSE: The control word is transmitted via the active network interface.
TRUE: Simulation of control word 1 is activated.
FALSE: The control word is transmitted via the active network interface.
TRUE: Simulation of control word 2 is activated.
FALSE: The control word is transmitted via the active network interface.
TRUE: Simulation of control word 3 is activated.
FALSE: The control word is transmitted via the active network interface.
TRUE: Simulation of control word 4 is activated.
FALSE: The control word is transmitted via the active network interface.
TRUE: Simulation of control word 5 is activated.
FALSE: The control word is transmitted via the active network interface.
TRUE: Simulation of control word 6 is activated.
FALSE: The control word is transmitted via the active network interface.
TRUE: Simulation of control word 7 is activated.
FALSE: The control word is transmitted via the active network interface.
Fieldbus/System bus
45 1 0
Status word 00:
45 111
-Bit 3 (VM Fault)
45 112
-Bit 6 (VM Jogging Busy)
45 113
-Bit 7 (VM Warning)
45 114
-Bit 8 (VM Halt Busy)
45 115
-Bits 25-31