20

Setting the Node Address

The second stage of the installation process is setting the node
address.
Set the PROFIBUS node address by rotating the rotary switches
located on the front of the XtraDrive-DP. Use a small flat
screwdriver to set the switches to an available node address, from
0 to 125. Note that x10 represents the hexadecimal sixteens place
(MSB) and x1 represents the units place (LSB). For example, to set a
node address of 52, you should set rotary switches to 34 Hex,
meaning that the MSB dial (x10) should be turned to 3 and the
LSB dial (x1) should be turned to 4.
0
0
x10
x1
The status of the node address rotary switches is only read
immediately after power on. You should take note of this fact when
changing the node address.
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France
Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20
Web : http: www.audin.fr - Email : info@audin.fr