19–32
INSPECTION
AVENSIS REPAIR MANUAL (RM1018E)
STARTING & CHARGING
–
1.
INSPECT GLOW PLUG RELAY ASSY
(a)
Using an ohmmeter, check for continuity between each
terminal.
Specified condition:
1 – 2
A34838
http://vnx.su
PRE–HEATING SYSTEM (1CD–FTV)
(Apply battery voltage terminals 3 and 4)
190JF–02
No continuity
Continuity