Toyota Avensis ZZT251 2003 Service And Repair Manual page 875

Table of Contents

Advertisement

16–38
AVENSIS REPAIR MANUAL (RM1018E)
COOLING
COOLING SYSTEM (1CD–FTV)
4.
INSPECT FINS BLOCKAGE
(a)
If fins are clogged, wash them with water or a steam
cleaner and dry with compressed air.
NOTICE:
Y
If the distance between the steam cleaner and the
core is too close, there is a possibility of damaging
the fins, so keep the following injection distance.
Injection Pressures
kPa (kgf/cm
A73603
2,942 to 4,903
(30 to 50, 427 to 711)
4,903 to 7,845
(50 to 80, 711 to 1,138)
Y
If the fins are bent, straighten them with a screwdriver
or pliers.
Y
Be careful not pour water directly onto electronic
components.
http://vnx.su
Injection Distance
2
, psi)
mm (in.)
300 (11.811)
500 (19.685)