The control thermostat
displays the following
codes:
LO
HI
E0, Er2, EE
For additional support, please contact your HP Indigo service center.

Chiller timer

When the time required by the chiller to reach working temperature hinders productivity,
you can turn the chiller on before the start of the shift. Use the chiller timer to turn the
chiller on before the press is turned on.
If the press enters the Ready state after being turned on, bypass the chiller timer. Chiller
bypass is the default timer state.
You can set the chiller timer to three On/Off functions per day. Setting the timer On turns
on the chiller independently of the press status. The press command of the chiller
overrides the chiller timer command.
Set the timer to On about 30 minutes before the start of a shift. Set the timer to Off 30
minutes after the start of a shift. This ensures that the chiller is turned off only at the end
of the workday.
The chiller timer is located behind the electronics cabinet, below the Main Power switch.
Figure 19-3. Chiller timer location
ENWW
Cause
Solution
The temperature has
If the compressor is
been below the setpoint
stopped, the water
for some minutes
temperature will rise to
normal eventually. If the
compressor is still
running, contact your
HP Indigo service
center.
The temperature has
Check that the cold
been above the
water setpoint is within
setpoint for some
the limits indicated (see
minutes
'Operating conditions'
on page 263).
The thermostat or
Contact your HP Indigo
temperature sensor is
service center.
faulty
Chiller timer
Electronics
cabinet, door
closed
Electronics
cabinet, door
open
Restart procedure
The chiller is still
working normally
The chiller is still
working normally
The chiller can be
restarted when the
faulty part is replaced.
Chiller timer 267