3
Top paper
guides
Front guide
adjustment knob
Side springs
Trailing edge
blower
Figure 11-19. Paper guide frame
4
5
6
7

Adjusting suction and blower flow rate

Adjust the suction blower flow rate whenever you replace the substrate with a new
substrate of different weight or size. Fine-tune the suction blower flow rate while the press
is transporting paper.
Increase the flow rate when printing on heavy substrate or on substrate with a rough
surface
Use the following procedure to increase the flow rate:
1
2
3
WARNING!
Pinch Hazard: Wait for four press revolutions to be sure that the paper is not fed before continuing
with the following procedure.
4
ENWW
Lower the paper guide frame.
Adjust the rear guide position until it touches the paper and supports the stack.
Adjust the front paper guide frame side spring bar.
Using the adjustment knobs, align the springs with the sheet. Verify that the springs
are aligned with the substrate.
Move the front paper guide to the stack, so that the springs press gently against it.
Allow the spring tongues to press against the left edge of the stack so they are
deflected slightly by 2 to 3 mm (0.08 to 0.12 inch).
Using the adjustment knob, adjust the trailing edge guide. Allow the guide to press
gently against the middle of the stack.
On the control panel, click the Consumables menu, and then select Substrate,
andTransport.
Set the following transport parameters:
• Feed—off
• Speed—normal
• Mode—multi shot
• Separation—multi separation
• Simplex
Click Run.
While the paper is fed, make sure that the press picks up only one sheet at a time.
The next sheet to be picked up should stay below the sheet separators.
Adjustment knobs
Rear guide
Trailing edge guide
Adjusting the input tray 163