Replacing The Bid; Diagnostics - HP Indigo press 3050 User Manual

Hide thumbs Also See for Indigo press 3050:
Table of Contents

Advertisement

Replacing the BID

Replace the BID station when the following occurs:
Before you start this procedure, make sure that you have the following items:

Diagnostics

The BID Diagnostic Wizard is used to diagnose BID problems off-line. BID diagnostics
should be performed before removing a suspect BID from the press. Use this wizard to
check BID units for correct flow rate, proper mechanical movement (Positive Developer
Not Rotating), correct BID biases, and for open and short circuits.
The BID wizard is automatic, and will either indicate that the BID is okay, or show a
specific error message.
To perform BID diagnostics, perform the following:
1
2
Figure 16-2. BID Diagnostic Wizard – BIDs Selection window
3
ENWW
image quality deteriorates
change of ink color is required
A new BID
BID stand
3-mm Allen key
Lint-free wipe
Imaging oil
On the control panel, click Standby.
From the Control Panel, click Diagnostics and BID Diagnostics. The BID Diagnostic
Wizard opens.
Select the BID units to be tested, and click Next.
Replacing the BID 221

Advertisement

Table of Contents
loading

Table of Contents