Overview; Replacing The Pip; Removing The Old Pip - HP Indigo press 3050 User Manual

Hide thumbs Also See for Indigo press 3050:
Table of Contents

Advertisement

Overview

Images are written on the photo-conductive imaging plate (PIP). Images are erased from
the PIP with each revolution. To work efficiently, the PIP must be capable of charging and
discharging continuously and to support sharp image definition. To prolong the PIP's
longevity, handle it with care, keep it as clean as possible, and protect it from direct light.
Take special care when opening the input door. Always make sure that the lights in the
press-room are dimmed when the PIP is exposed.

Replacing the PIP

Perform the following procedure to replace the PIP when it is damaged or aged. Before
you replace the PIP, make sure you have the following items:

Removing the old PIP

To remove the PIP, follow the instructions below:
1
2
3
4
5
6
136 Chapter 10 PIP
PIP pack (one unit or seven units)
Plastic squeeze bottle with 500 ml (16.9 oz) of imaging oil (The spout of the bottle
should be at a 45° angle with a nozzle size 1.5 to 2.0 mm [0.06 to 0.08 inch]).
Lint-free wipes
Chemical-resistant gloves
In the control panel, click Standby. The press changes to the Standby state.
Wait until the ITM drum reaches room temperature.
Open the upper feed door and open the ITM hood.
Release the conveyor latch and lift the conveyor.
Remove the ITM hood. See 'Removing the ITM hood' on page 131.
Lift the PIP protective cover.