Overview

The press uses a water chiller to regulate ink and press temperature. Both the ink tanks
and the blanket emit heat. The chilled water runs continuously through the press and ink
tanks to keep these parts at their nominal predefined temperatures.
The cold water comes in from the water chiller. The water chiller connects to the press
with a hose. The hose length should not exceed 20 m (65 ft). When there are height
differences between the chiller location and the press location. The differences should not
exceed 10 m (32 ft).
Monitor water chillers that are not connected permanently to a water source for water
replenishing. You may need to replace the water and water filter, according to
maintenance instructions.

Chiller type

HP Indigo presses are equipped with the following chiller:
Manufacturers can modify chiller models or model names. Contact the chiller
manufacturer for details.
Contact your local HP Indigo service center for specific inspection and maintenance
procedures for the chiller.
Note
For Orion chillers used in Japan, refer to the Orion chiller user guide, or contact your local HP
Indigo service center.
Electrical connection
The required electrical supply for each version is listed below.
Input voltage (volts)
230
400

Warnings

The basic maintenance should be carried out by properly trained personnel, and if
necessary, under the supervision of a person qualified for this job.
WARNING!
The ultracool units must always operate with the panels closed to enable the inlet of fresh air
only through the condenser.
262 Chapter 19 Chiller
ultrafilter ultracool mini (0140 HP Indigo), 50/60 Hz
Number of phases
3
3
Line frequency (Hz)
60
50