5.4 Setting Input Types
0
in-ta
L
(IN-TA)
0
in-tb
L
(IN-TB)
func
0
f1
Displays "L0."
in-ta
0
00
in-ta
0
00
in-ta
0
01
in-tb
0
00
1234.5
1234.5
Set the input type to match the connected input device.
Parameter
Input type A
in-ta
Input type B
in-tb
(See note.)
Note: Not displayed on the K3HB-C when F3 has been selected.
Parameter Setting Procedure: Input Type
The following procedure shows an example using the K3HB-R.
A Press the L [LEVEL] Key for at least 3 s in RUN level to move to
L
the initial setting level.
3 s min.
0" is displayed on the level/bank display to indicate the initial
• "
L
setting level.
B If the PV display is not "in-ta" or "in-tb," press the M [MODE]
M
Key to display the desired parameter.
C Press the S [SHIFT] Key to make the SV display flash.
S
• The setting can be changed when the SV display starts to
flash.
D Use the U [UP] Key to change the set value.
U
E Press the M [MODE] Key to switch to the next parameter.
M
• The set value is registered.
F Press the L [LEVEL] Key for at least 1 s to return to the RUN
L
level.
1 s min.
5.4 Setting Input Types
Initial setting level
Set value
Meaning of set value
00
Open collector (NO) or
voltage pulse (H)
01
Open collector (NC) or
voltage pulse (L)
10
Relay contact (NO) or voltage
pulse (H)
11
Relay contact (NO) or voltage
pulse (L)
00
No-voltage contact (NO) or
voltage pulse (H)
01
No-voltage contact (NC) or
voltage pulse (L)
10
Contact (NO) or voltage
pulse (H)
11
Contact (NC) or voltage pulse
R
P C
(L)
5-27