Specifications - Omron K35-2 Manual

Digital indicators
Hide thumbs Also See for K35-2:
Table of Contents

Advertisement

Specifications

■ Ratings
Power supply voltage
Allowable power supply voltage range
Power consumption
(See note 1.)
Current consumption
Input
A/D conversion method
External power supply
Event inputs (See
Timing input
note 2.)
Startup compensa-
tion timer input
Hold input
Reset input
Forced-zero input
Bank input
Output ratings (de-
Relay output
pends on the mod-
el)
Transistor output
Linear output
Display method
Main functions
Ambient operating temperature
Ambient operating humidity
Storage temperature
Altitude
Accessories
Note: 1. DC power supply models require a control power supply capacity of approximately 1 A per Unit when power is turned ON. Particular
attention is required when using two or more DC power supply models. The OMRON S8VS-series DC Power Supply Unit is recommend-
ed.
2. PNP input types are also available.
3. For K3HB-series DeviceNet models, use only the DeviceNet Connector included with the product. The crimp terminals provided are for
Thin Cables.
100 to 240 VAC (50/60 Hz), 24 VAC/VDC, DeviceNet power supply: 24 VDC
85% to 110% of the rated power supply voltage, DeviceNet power supply: 11 to 25 VDC
100 to 240 V: 18 VA max. (max. load)
24 VAC/DC: 11 VA/7 W max. (max. load)
DeviceNet power supply: 50 mA max. (24 VDC)
DC voltage, DC current, AC voltage, AC current
Delta-Sigma method
See Sensor Power Supply/Output Type Codes
NPN open collector or no-voltage contact signal
ON residual voltage: 3 V max.
ON current at 0 Ω : 17 mA max.
Max. applied voltage: 30 VDC max.
OFF leakage current: 1.5 mA max.
NPN open collector or no-voltage contact signal
ON residual voltage: 2 V max.
ON current at 0 Ω : 4 mA max.
Max. applied voltage: 30 VDC max.
OFF leakage current: 0.1 mA max.
250 VAC, 30 VDC, 5 A (resistive load)
Mechanical life expectancy: 5,000,000 operations, Electrical life expectancy: 100,000 operations
Maximum load voltage: 24 VDC, Maximum load current: 50 mA, Leakage current: 100 µ A max.
Linear output 0 to 20 mA DC, 4 to 20 mA:
Load: 500 Ω max, Resolution: Approx. 10,000, Output error: ±0.5% FS
Linear output 0 to 5 VDC, 1 to 5 VDC, 0 to 10 VDC:
Load: 5 k Ω max, Resolution: Approx. 10,000, Output error: ±0.5% FS
(1 V or less: ±0.15 V; not output for 0 V or less)
Negative LCD (backlit LED) display
7-segment digital display (Character height: PV: 14.2 mm (green/red); SV: 4.9 mm (green)
Scaling function, measurement operation selection, averaging, previous average value comparison, forced-ze-
ro, zero-limit, output hysteresis, output OFF delay, output test, teaching, display value selection, display color
selection, key protection, bank selection, display refresh period, maximum/minimum hold, reset
− 10 to 55 ° C (with no icing or condensation)
25% to 85%
− 25 to 65 ° C (with no icing or condensation)
2,000 m max.
Watertight packing, 2 fixtures, terminal cover, unit stickers, instruction manual. DeviceNet models also include
a DeviceNet connector (Hirose HR31-5.08P-5SC(01)) and crimp terminals (Hirose HR31-SC-121) (See note
3.)
K3HB-X
Process Indicator
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

K3hb series

Table of Contents