3.19 Commissioning of SSI encoders
Note
The alarm A07569 "Encoder identification active" remains pending while the identification
task has not yet completed.
Note
If the connected SSI encoder cannot be identified, alarm F3x153 "Encoder x: Identification
failed" is issued and the value 0, "No encoder", is entered in parameter p0400. This encoder
must then be configured manually.
3.19.3

Overview of important parameters

Overview of important parameters (see SINAMICS S120/S150 List Manual)
• p0400[0...n]
• p0404[0...n]
• p0407[0...n]
• p0408[0...n]
• p0421[0...n]
• p0422[0...n]
• p0423[0...n]
• p0427[0...n]
• p0428[0...n]
• p0429[0...n]
• p0434[0...n]
• p0435[0...n]
• p0436[0...n]
• p0446[0...n]
• p0447[0...n]
• p0448[0...n]
• p0449[0...n]
Changed for SSI encoder identification
1)
280
Encoder type selection
1)
Encoder configuration active
1)
Linear encoder scale
1)
Rotary encoder pulse No.
1)
Absolute encoder rotary multiturn resolution
1)
Absolute encoder linear measuring increments resolution
1)
Absolute encoder rotary singleturn resolution
1)
SSI encoder baud rate
SSI encoder monoflop time
SSI encoder configuration
1)
SSI encoder error bit
1)
SSI encoder alarm bit
1)
SSI encoder parity bit
1)
SSI encoder bit count before the absolute value
SSI encoder bit count absolute value
1)
SSI encoder bit count after the absolute value
1)
SSI encoder bit count filler bits
1)