Siemens Sinamics s120 Commissioning Manual page 314

With starter
Hide thumbs Also See for Sinamics s120:
Table of Contents

Advertisement

Diagnostics
4.1 Diagnostics via LEDs
Control Unit 310-2 PN while powering up
Table 4- 12
Load software
RDY
COM
Orange
Orange
Red
Red
Red
Red
Red
Red
Flashing light 2
Hz
Red
Red
Flashing light 2
Flashing light 2
Hz
Hz
Table 4- 13
Firmware
RDY
COM
Red
Orange
Red
Off
Off
Red
Red
Red
Flashing light
Flashing light
0.5 Hz
0.5 Hz
Orange
Off
Control Unit 310-2 PN in operation
Table 4- 14
Description of the LEDs during operation of the CU310-2 PN
LED
Color
RDY
-
(READY)
Green
314
LED
OUT>5V
Orange
Off
Off
Off
Off
LED
OUT>5V
Off
Off
Off
Off
Off
State
Description / cause
Off
Electronic power supply is missing or outside
permissible tolerance range.
Continuous light
The unit is ready for operation.
Cyclic DRIVE-CLiQ communication is in pro-
gress.
Flashing light 0.5
Commissioning/reset
Hz
Flashing light 2 Hz Writing to the memory card.
State
MOD
Orange
POWER ON
Off
Hardware reset After pressing the RESET button
Off
BIOS loaded
Off
BIOS error
Off
File error
State
MOD
Off
Firmware load-
ing
Off
Firmware load-
ed
Off
Firmware
check
(no CRC error)
Off
Firmware
check
(CRC error)
Off
Firmware ini-
tialization
Commissioning Manual, (IH1), 07/2016, 6SL3097-4AF00-0BP5
Comment
All LEDs light up for approx. 1 s
the LEDs light up for approx. 1 s
-
Error occurred while loading the
BIOS
Memory card not inserted or faulty
Software on memory card not
present or corrupted
Comment
COM-LED flashing without specific
flashing frequency
-
-
CRC is incorrect
-
Remedy
Check the power sup-
ply
-
-
-
STARTER Commissioning Manual

Advertisement

Table of Contents
loading

Table of Contents