Commissioning
3.22 Basic Operator Panel 20 (BOP20)
Information on the keys
Table 3- 29
Keys
Key
Name
ON
OFF
Functions
Parameter
Raise
Lower
BOP20 functions
Table 3- 30
Functions
Name
Backlighting
Changeover active drive
Units
Access level
Parameter filter
Selecting the operating
display
User parameter list
294
Meaning
Powering up the drives for which the command "ON/OFF1" should come from the BOP.
Binector output r0019.0 is set using this key.
Powering down the drives for which the commands "ON/OFF1", "OFF2" or "OFF3" should come
from the BOP.
The binector outputs r0019.0, .1 and .2 are simultaneously reset when this key is pressed. After
the key has been released, binector outputs r0019.1 and .2 are again set to a "1" signal.
Note:
The effectiveness of these keys can be defined by appropriately parameterizing the BICO (e.g.
using these keys it is possible to simultaneously control all of the existing drives).
The significance of this key depends on the actual display.
Note:
The effectiveness of this key to acknowledge faults can be defined using the appropriate BiCo
parameterization.
The significance of this key depends on the actual display.
If this key is pressed for 3 s, the "Copy RAM to ROM" function is executed. The "S" displayed on
the BOP disappears.
The significance of these keys is dependent on the actual display and is used to increase or
decrease values.
Description
The backlighting can be set using p0007 in such a way that it switches itself off automatically
after the set time if no actions are carried out.
From the BOP perspective the active drive is defined using p0008 or using the keys "FN" and
"Arrow up".
The units are not displayed on the BOP.
The access level for the BOP is defined using p0003.
The higher the access level, the more parameters can be selected using the BOP.
Using the parameter filter in p0004, the available parameters can be filtered corresponding to
their particular function.
Actual values and setpoints are displayed on the operating display.
The operating display can be set using p0006.
Using the user parameter list in p0013, parameters can be selected for access.
STARTER Commissioning Manual
Commissioning Manual, (IH1), 07/2016, 6SL3097-4AF00-0BP5