Table 4- 43
Meaning of the OPT LED on the Control Unit
LED
Color
State
OPT
OFF
Green
Continuous
light
Flashing
light
0.5 Hz
Red
Continuous
light
Flashing
light
0.5 Hz
Flashing
light
2 Hz
Orange
Flashing
light
0.5 Hz
STARTER Commissioning Manual
Commissioning Manual, (IH1), 07/2016, 6SL3097-4AF00-0BP5
Description, cause
The electronics power supply is missing or outside the per-
missible tolerance range.
Communication Board either defective or not inserted.
Communication Board is ready and cyclic communication is
taking place.
The Communication Board is ready, but cyclic communica-
tions is not running.
Possible causes:
Communication is being established.
At least one fault is present.
Cyclic communication via PROFINET has not yet been
established. However, non-cyclic communications are pos-
sible. SINAMICS waits for a parameterizing/configuring
telegram
The firmware update into the CBE25 has been completed
with an error.
Possible causes:
The CBE25 is defective.
The memory card for the Control Unit is defective.
In this state the CBE25 cannot be used.
There is a communications error between the Control Unit
and the CBE25.
Possible causes:
The CBE25 is defective.
The CBE25 was withdrawn after booting.
Firmware is being updated.
Diagnostics
4.1 Diagnostics via LEDs
Remedy
Correctly insert the
board, if required,
replace.