Image 3-58
Image 3-59
STARTER Commissioning Manual
Commissioning Manual, (IH1), 07/2016, 6SL3097-4AF00-0BP5
Phase U motor 1 may not lag behind EMF phase U motor 2 by more than 10°
EMF phase U motor 1 may not lead EMF phase U motor 2 by more than 10°
3.13 Commissioning of SIMOTICS L-1FN3 linear motors
Commissioning
209