Commissioning
3.6 Commissioning U/f vector control booksize format for the first time
What?
4.
Configuring the
drives
For drives connected to the drive unit, which during the automatic configuration do not communicate with the Control Unit
via DRIVE-CLiQ, you must manually configure and transfer them into the drive topology. These devices can only be in-
serted in the offline mode. In this case, perform the commissioning with step 4.1.
If the drives have already been created by the automatic configuration, click "Configuration" > "Configure DDS... " under
the drive. Then continue from step 4.2. Settings of the power unit data and for motors with DRIVE-CLiQ interface, the mo-
tor data is also already pre-assigned based on the electronic type plate.
4.1
Inserting drives
4.2
Control structure
4.3
Power unit
4.4
Configuration,
power unit BICO
interconnection
4.5
Configuring addi-
tional data
NOTICE
Damage to a sine-wave filter if it is not activated during commissioning
The sine-wave filter may be damaged if it is not activated during commissioning.
• Activate use of a sine-wave filter during commissioning via parameter p0230 = 3.
138
How?
You must individually configure the drives in the offline mode.
The wizard displays the data determined automatically from the
electronic type plate.
1. Double-click in the project tree on "Drives".
2. Double-click the "Insert drives" entry.
3. Enter a name for the drive.
4. For the drive object, select "VECTOR".
5. Click "OK".
1. Select function modules.
2. Switch the closed-loop control to "V/f control".
3. Select the required control mode.
4. Click "Continue >".
1. Enter a name for the component.
2. Select the DC supply voltage.
3. Select the cooling type.
4. Select the type.
The available components are now in the selection list.
5. Select the required power unit.
6. Click "Continue >".
If an infeed without DRIVE-CLiQ connection is used, a message
is displayed stating that the operating signal must be connected.
1. In the following dialog "Infeed in operation", set parameter
p0864 to the binector output of the digital input to which the
operating feedback signal of the infeed is interconnected.
2. Click "Continue >".
In this window, you can additionally select the following
Various output filters
A Voltage Sensing Module
A parallel connection
STARTER Commissioning Manual
Commissioning Manual, (IH1), 07/2016, 6SL3097-4AF00-0BP5
Comment
-
-
-
-
-
With this dialog window,
the configuration of the
Motor Module has been
completed.