Siemens Sinamics s120 Commissioning Manual page 141

With starter
Hide thumbs Also See for Sinamics s120:
Table of Contents

Advertisement

What?
6.2
Enable Motor
Module
6.3
Ramp-function
generator
6.4
Setpoint
STARTER Commissioning Manual
Commissioning Manual, (IH1), 07/2016, 6SL3097-4AF00-0BP5
3.6 Commissioning U/f vector control booksize format for the first time
How?
Enable signals for the Motor Module (drive_1)
p0840 = 722.0 ON/OFF1
p0844 = 722.1 1. OFF2
p0845 = 1 2. OFF2
p0848 = 722.2 1. OFF3
p0849 = 1 2. OFF3
p0852 = 722.3 Enable operation
Ramp-function generator
p1140 = 1 Ramp-function generator enable
p1141 = 1 Ramp-function generator start
p1142 = 1 Enable setpoint
Specify setpoint
p1001 = 40 Fixed setpoint 1
Commissioning
Comment
See function diagram
[2501]
See function diagram
[3060]
See function diagram
[3010]
141