The following parameters can be optionally entered:
Table 3- 16
Parameter
p0320
p0322
p0341
p0342
p0344
p0352
p0353
Table 3- 17
Parameter
p0350
p0354
p0356
p0358
p0360
STARTER Commissioning Manual
Commissioning Manual, (IH1), 07/2016, 6SL3097-4AF00-0BP5
Optional motor data
Description
Motor rated magnetizing current / short-
circuit current
Maximum motor speed
Motor moment of inertia
Moment of inertia ratio between the total
and motor
Motor weight (for thermal motor type)
Cable resistance (component of the stator
resistance)
Motor series inductance
Equivalent circuit diagram for motor data
Description
Motor stator resistance, cold
Motor rotor resistance, cold
Motor stator leakage inductance
Motor rotor leakage inductance
Motor magnetizing inductance
3.14 Commissioning induction motors (ASM)
Comment
-
-
-
-
-
Especially for vector control without
encoder (SLVC) this parameter has a
significant influence on the quality of
the closed-loop control at low speeds.
This parameter is required for the
correct function of flying restart oper-
ating mode.
-