Siemens Sinamics s120 Commissioning Manual page 137

With starter
Hide thumbs Also See for Sinamics s120:
Table of Contents

Advertisement

What?
3.1
Inserting
an infeed unit
3.2
Infeed
3.3
Infeed - additional
data
3.4
Process data ex-
change
(infeed)
3.5
Configuration,
summary
NOTICE
Damage to the infeed for control using another Control Unit
If the infeed is controlled from another Control Unit, then the ready signal of the infeed must
be connected to parameter p0864 "infeed ready" of the drive through a digital input/output.
If this is not taken into account, the infeed may be damaged.
STARTER Commissioning Manual
Commissioning Manual, (IH1), 07/2016, 6SL3097-4AF00-0BP5
3.6 Commissioning U/f vector control booksize format for the first time
How?
If there is no DRIVE-CLiQ connection to the Control Unit, then
you must manually enter the data of the infeed unit using the
wizard.
1. Double-click in the project tree on "Infeeds".
2. Double-click "Insert infeed".
3. Enter a name for the infeed.
4. Select the type.
5. Click "OK".
1. Enter a component name.
2. Select the line voltage range.
3. Select the cooling type.
4. Select the type.
The available components are now in the selection list.
5. Select the required infeed from the list.
6. Click "Continue >".
1. Activate the line/DC-link identification when switching-on for
the first time.
2. Accept the device supply voltage from the previous window.
The rated line frequency is determined automatically.
3. If applicable, enter the number of parallel infeeds.
4. Where relevant, select a Voltage Sensing Module.
5. Where relevant, select an external Braking Module.
6. Click "Continue >".
One of three telegrams can be selected for communication: 370,
371 and 999.
1. Select the required telegram.
2. Click "Continue >".
Configuration of the infeed unit completed. A summary is dis-
played.
1. Click "Complete".
Commissioning
Comment
If the line environment or
DC-link components are
changed, line/DC-link iden-
tification should be repeat-
ed.
-
-
-
The infeed unit data can be
copied to the clipboard for
plant documentation pur-
poses and then added to a
text program, for example.
137

Advertisement

Table of Contents
loading