Communication Board Cbc10 For Canopen - Siemens Sinamics s120 Commissioning Manual

With starter
Hide thumbs Also See for Sinamics s120:
Table of Contents

Advertisement

LED
Color
Status
Green/red Flashing
light
2 Hz
Green/
Flashing
orange
light
or
Red/
orange
The parameter for activating component recognition can be taken from the following reference:
1)
Reference: /LH1/ SINAMICS S120/S150 List Manual
Each channel has a multifunction LED.
4.1.3.5

Communication Board CBC10 for CANopen

Table 4- 37
Meaning of the LEDs on the Communication Board CAN CBC10
LED
Color
State
OPT
Off
on the
Control
Unit
Green
LED ON
LED Blinking
LED Single
flash
Red
LED ON
LED Single
flash
LED Double
flash
STARTER Commissioning Manual
Commissioning Manual, (IH1), 07/2016, 6SL3097-4AF00-0BP5
Description, cause
Firmware download is complete. The system waits for
POWER ON.
Component recognition via LED is activated
Note:
Both options depend on the LED status when component
recognition is activated.
Description, cause
Electronic power supply is missing or outside permissible
tolerance range.
Communication Board either defective or not inserted.
OPERATIONAL
PREOPERATIONAL
No PDO communication possible
STOPPED
Only NMT communication possible
BUS OFF
ERROR PASSIVE MODE
The error counter for "error passive" has reached the value
127. After the SINAMICS drive system was booted no fur-
ther active CAN component was on the bus.
Error Control Event, a Guard Event has occurred
4.1 Diagnostics via LEDs
Remedy
Carry out a POWER
ON.
.
1)
Remedy
Check baud rate
Check cabling
Check baud rate
Check cabling
Check connection to
CANopen master
Diagnostics
329

Advertisement

Table of Contents
loading