3.16 Commissioning permanent-magnet synchronous motors
Temperature protection can be implemented using a temperature sensor
(KTY/PT1000/PTC). In order to achieve a high torque accuracy, we recommend that a KTY
or PT1000 temperature sensor is used.
Table 3- 18
Parameter
p0304
p0305
p0307
p0310
p0311
If the torque constant k
can calculate this value from the rated motor data (index n) or from the stall current I
stall torque M
Table 3- 19
Parameter
p0314
p0316
p0320
p0322
p0323
p0325
p0327
p0328
p0329
p0341
p0342
226
Motor data
Description
Rated motor voltage
Rated motor current
Rated motor power
Rated motor frequency
Rated motor speed
is not stamped on the type plate or specified in the data sheet, you
T
as follows:
o
Optional data
Description
Motor pole pair number
Motor torque constant
Motor rated magnetizing current / short-
circuit current
Maximum motor speed
Maximum motor current
Motor pole position information
Optimum motor load angle
PE spindle, reluctance torque constant
Motor pole position identification current
Motor moment of inertia
Moment of inertia ratio
total to motor
Comment
If this value is not known, a "0" can
also be entered. Using this value, the
stator leakage inductance can be
more precisely calculated (p0356,
p0357).
-
-
-
-
Comment
-
-
This is used for the field weakening
characteristic
Maximum mechanical speed
Demagnetization protection
-
-
-
-
For speed controller precontrol
-
STARTER Commissioning Manual