Siemens Sinamics s120 Commissioning Manual page 152

With starter
Hide thumbs Also See for Sinamics s120:
Table of Contents

Advertisement

Commissioning
3.7 Commissioning the vector control chassis format for the first time
What?
6.2
Enable the Motor
Module
6.3
Ramp-function
generator configu-
ration
152
How?
Enable signals for the Motor Module (drive_1):
p0840 = 722.0 ON/OFF1
p0844 = 722.1 1. OFF2
p0845 = 1 2. OFF2
p0848 = 722.2 1. OFF3
p0849 = 1 2. OFF3
p0852 = 722.3 Enable operation
p0864 = 863.0 Infeed operation
Ramp-function generator
p1140 = 1 Ramp-function generator enable
p1141 = 1 Ramp-function generator start
p1142 = 1 Enable setpoint
STARTER Commissioning Manual
Commissioning Manual, (IH1), 07/2016, 6SL3097-4AF00-0BP5
Comment
See function diagram
[2501]
See function diagram
[3060]

Advertisement

Table of Contents
loading