AudioCodes Mediant 3000 User Manual page 871

Gateway & enterprise sbc, family of media gateways & session border controllers
Hide thumbs Also See for Mediant 3000:
Table of Contents

Advertisement

User's Manual
Parameter
Web/EMS: PCM Law Select
[PCMLawSelect]
Web/EMS: Idle PCM Pattern
[IdlePCMPattern]
Web/EMS: Idle ABCD Pattern
[IdleABCDPattern]
Web/EMS: TDM Bus Clock
Source
[TDMBusClockSource]
Web/EMS: TDM Bus Local
Reference
[TDMBusLocalReference]
Web/EMS: TDM Bus Enable
Fallback
[TDMBusEnableFallback]
Web: TDM Bus Fallback Clock
Source
Version 6.8
[2] 4 Mbps
[3] 8 Mbps
[4] 16 Mbps (default)
Determines the type of pulse-code modulation (PCM) companding
algorithm law in input and output TDM bus.
[1] Alaw
[3] MuLaw
The default value is automatically selected according to the
Protocol Type of the selected trunk: E1 defaults to ALaw, T1
defaults to MuLaw. If the Protocol Type is set to NONE, the default
is MuLaw.
Notes:
For this parameter to take effect, a device reset is required.
Typically, A-Law is used for E1 spans and Mu-Law for T1/J1
spans.
Defines the PCM Pattern that is applied to the E1/T1 timeslot (B-
channel) when the channel is idle.
The range is 0 to 255. The default is set internally according to the
Law select 1 (0xFF for Mu-Law; 0x55 for A-law).
Note: For this parameter to take effect, a device reset is required.
Defines the ABCD (CAS) Pattern that is applied to the CAS
signaling bus when the channel is idle.
The valid range is 0x0 to 0xF. The default is -1 (i.e., default pattern
is 0000).
Notes:
For this parameter to take effect, a device reset is required.
This parameter is applicable only when using PSTN interface
with CAS protocols.
Determines the clock source to which the device synchronizes.
[1] Internal = (Default) Generate clock from local source.
[4] Network = Recover clock from PSTN line.
Notes:
For this parameter to take effect, a device reset is required.
This parameter is not required when operating in BITS mode.
Defines the physical Trunk ID from which the device recovers
(receives) its clock synchronization.
The range is 0 to the maximum number of Trunks. The default is 0.
Note: This parameter is applicable only if the parameter
TDMBusClockSource is set to 4 and the parameter
TDMBusPSTNAutoClockEnable is set to 0.
Defines the automatic fallback of the clock. This sets the fallback
clock method between primary and secondary BITS clock
references.
[0] Manual (default)
[1] Auto Non-Revertive
[2] Auto Revertive
Determines the fallback clock source on which the device
synchronizes in the event of a clock failure.
871
51. Configuration Parameters Reference
Description
Mediant 3000

Advertisement

Table of Contents
loading

Table of Contents