Note:
the Sending Complete IE, you must configure the ISDNOutCallsBehavior parameter
to USER SENDING COMPLETE [2].
For more information on the above mentioned parameters, see PSTN Parameters on page
865. For configuring ISDN overlap dialing using the Web interface, see ''Configuring Trunk
Settings'' on page 361.
22.9

Redirect Number and Calling Name (Display)

The following tables define the device's redirect number and calling name (Display) support
for various ISDN variants according to NT (Network Termination) / TE (Termination
Equipment) interface direction:
NT/TE Interface
NT-to-TE
TE-to-NT
NT/TE Interface
NT-to-TE
TE-to-NT
* When using ETSI DivertingLegInformation2 in a Facility IE (not Redirecting Number IE).

22.10 SDH / SONET Configuration

Note:
blade.
The device supports STM-1 and OC-3 optical fiber transmission modes. Optical fiber
transmission is configured using the PSTNTransmissionType parameter (set to 1) and the
fiber mode is defined using the SdhFbrGrp_SdhSonetMode parameter (set to 1 for STM-1,
or 2 for OC-3). The device supports Automatic Protection Switch (APS) for these
interfaces.
STM-1 interface: provides short range Synchronous Digital Hierarchy (SDH) STM-1
interface compliant with ITU-T G.707 and ITU-T G.957. The interface operates at
155.52 Mbps over a single-mode fiber span. The device supports VC-4 payload at the
STM-1 signal level. The device supports the asynchronous VC-12 mapping (mapping
of E1s into VC12s and multiplexing of 63 VC12 into an STM-1 frame).
Relevant parameters:
PSTNTransmissionType - set to 'Optical SONET or SDH' (1).
Version 6.8
For IP-to-Tel overlap dialing, to send ISDN Setup messages without including
Table 22-2: Calling Name (Display)
DMS-100
NI-2
Yes
Yes
Yes
Yes
Table 22-3: Redirect Number
DMS-100
NI-2
Yes
Yes
Yes
Yes
This section is applicable only to PSTN STM-1 / OC-3 ports on the TP-6310
4/5ESS
Yes
Yes
4/5ESS
Yes
Yes
383
22. Digital PSTN
Euro ISDN
QSIG
Yes
Yes
No
Yes
Euro ISDN
QSIG
Yes
Yes
Yes*
Yes
Mediant 3000