Parameter
Total Ingress Bandwidth
[BWProfile_TotalIngressBandwidth]
Warning Threshold
[BWProfile_WarningThreshold]
Hysteresis
[BWProfile_hysteresis]
Generate Alarm
[BWProfile_GenerateAlarms]
User's Manual
Defines the total (video and audio) incoming bandwidth
threshold (in Kbps).
Defines the threshold (in percentage) of the bandwidth
thresholds that if exceeded is considered a Warning alarm
(Green-Yellow threshold). This applies to any of the
configured bandwidth thresholds. The Hysteresis is also
added to this Warning threshold. For example, if set to 70%
and the Hysteresis to 10%, when the current outgoing voice
traffic exceeds 80% of the configured threshold, the Yellow
state occurs and a Warning threshold alarm is sent if
'Generate Alarm' is set to Enable.
Defines the bandwidth fluctuation (change) from the
bandwidth threshold value (in percentage). The threshold is
considered crossed if bandwidth exceeds the configured
threshold plus this hysteresis, and a Red state occurs. For
example, assume this parameter is set to 10% and the
configured bandwidth threshold is set to 64000 Kbps. If
current bandwidth reaches 70,400 Kbps (additional 10%),
the threshold is considered crossed.
Enables the generation of an SNMP alarm if the threshold
(with the hysteresis) is crossed.
[0] Disable (default)
[1] Enable
If enabled, an alarm is sent if one of the following scenarios
occurs:
Warning threshold is exceeded (Warning severity -
Yellow threshold).
Any configured bandwidth threshold is exceeded (Major
severity - Red threshold).
264
Mediant 3000
Description
Document #: LTRT-89738