Notes:
Don't modify the default values unless you fully understand the implications of the
changes and know the default values. Every change affects the configuration of
the state machine parameters and the call process related to the trunk you are
using with this state machine.
You can modify CAS state machine parameters only if the following conditions are
met:
1) Trunks are inactive (stopped), i.e., the 'Related Trunks' field displays the trunk
number in green.
2) State machine is not in use or is in reset, or when it is not related to any trunk. If
it is related to a trunk, you must delete the trunk or de-activate (Stop) the trunk.
Field values displaying '-1' indicate CAS default values. In other words, CAS state
machine values are used.
The modification of the CAS state machine occurs at the CAS application
initialization only for non-default values (-1).
For more information on the CAS Protocol table, refer to the CAS Protocol Table
Configuration Note.
Table 22-1: CAS State Machine Parameters Description
Parameter
Generate Digit On Time
[CasStateMachineGenerateDigitOn
Time]
Generate Inter Digit Time
[CasStateMachineGenerateInterDigi
tTime]
DTMF Max Detection Time
[CasStateMachineDTMFMaxOnDete
ctionTime]
DTMF Min Detection Time
[CasStateMachineDTMFMinOnDete
ctionTime]
MAX Incoming Address Digits
[CasStateMachineMaxNumOfIncomi
ngAddressDigits]
MAX Incoming ANI Digits
[CasStateMachineMaxNumOfIncomi
ngANIDigits]
Collet ANI
[CasStateMachineCollectANI]
User's Manual
Generates digit on-time (in msec).
The value must be a positive value. The default is -1 (use
value from CAS state machine).
Generates digit off-time (in msec).
The value must be a positive value. The default is -1 (use
value from CAS state machine).
Detects digit maximum on time (according to DSP detection
information event) in msec units.
The value must be a positive value. The default is -1 (use
value from CAS state machine).
Detects digit minimum on time (according to DSP detection
information event) in msec units. The digit time length must
be longer than this value to receive a detection. Any number
may be used, but the value must be less than
CasStateMachineDTMFMaxOnDetectionTime.
The value must be a positive value. The default is -1 (use
value from CAS state machine).
Defines the limitation for the maximum address digits that
need to be collected. After reaching this number of digits, the
collection of address digits is stopped.
The value must be an integer. The default is -1 (use value
from CAS state machine).
Defines the limitation for the maximum ANI digits that need
to be collected. After reaching this number of digits, the
collection of ANI digits is stopped.
The value must be an integer. The default is -1 (use value
from CAS state machine).
In some cases, when the state machine handles the ANI
collection (not related to MFCR2), you can control the state
machine to collect ANI or discard ANI.
370