Gateway & enterprise sbc, family of media gateways & session border controllers
Hide thumbs Also See for Mediant 3000:
Table of Contents

Advertisement

2.
Establish serial communication with the device using a terminal emulator program
such as HyperTerminal, with the following communication port settings:
Baud Rate: 115,200 bps
Data Bits: 8
Parity: None
Stop Bits: 1
Flow Control: None
3.
At the prompt, type the login username (default is "Admin" - case sensitive):
login: Admin
4.
At the prompt, type the password (default is "Admin" - case sensitive):
password: Admin
5.
At the prompt, type the following command to access the Configuration folder:
/>CONF
6.
View the current network settings, by typing the following command:
/CONFiguration>GCP IP
7.
Change the network settings, by typing the following command:
/CONFiguration>SCP IP <IP address> <subnet mask> <Default Gateway>
You must enter all three network parameters, each separated by a space, for
example:
/CONFiguration>SCP IP 10.13.77.7 255.255.0.0 10.13.0.1
8.
Save your changes and reset the device, by typing the following command:
/CONFiguration>SAR
9.
For HA mode, repeat the above steps for the second blade.
10.
Cable the device to your network. You can now access the device's management
interface using this new OAMP IP address.