AudioCodes Mediant 3000 User Manual page 782

Gateway & enterprise sbc, family of media gateways & session border controllers
Hide thumbs Also See for Mediant 3000:
Table of Contents

Advertisement

Parameter
[ProxySet]
Registrar Parameters
Web: Enable Registration
EMS: Is Register Needed
[IsRegisterNeeded]
Web/EMS: Registrar Name
[RegistrarName]
Web: Registrar IP Address
EMS: Registrar IP
[RegistrarIP]
User's Manual
redundancy mechanisms.
The format of the ini file table parameter is as follows:
[ ProxySet ]
FORMAT ProxySet_Index = ProxySet_ProxyName,
ProxySet_EnableProxyKeepAlive,
ProxySet_ProxyKeepAliveTime,
ProxySet_ProxyLoadBalancingMethod,
ProxySet_IsProxyHotSwap, ProxySet_SRD,
ProxySet_ClassificationInput,
ProxySet_ProxyRedundancyMode,
ProxySet_DNSResolveMethod,
ProxySet_KeepAliveFailureResp,
ProxySet_SuccessDetectionRetries,
ProxySet_SuccessDetectionInterval,
ProxySet_FailureDetectionRetransmissions;
[ \ProxySet ]
For a description of this table, see ''Configuring Proxy Sets'' on
page 296.
For configuring the IP addresses per Proxy Set in the ini file,
use the ProxyIP parameter.
Enables the device to register to a Proxy/Registrar server.
[0] Disable = (Default) The device doesn't register to
Proxy/Registrar server.
[1] Enable = The device registers to Proxy/Registrar server
when the device is powered up and at every user-defined
interval (configured by the parameter RegistrationTime).
Notes:
This parameter is applicable only to the Gateway
application.
The device sends a REGISTER request for each channel or
for the entire device (according to the AuthenticationMode
parameter).
Defines the Registrar domain name. If specified, the name is
used as the Request-URI in REGISTER messages. If it isn't
specified (default), the Registrar IP address, or Proxy name or
IP address is used instead.
The valid range is up to 100 characters.
Note: This parameter is applicable only to the Gateway
application.
Defines the IP address (or FQDN) and port number (optional)
of the Registrar server. The IP address is in dotted-decimal
notation, e.g., 201.10.8.1:<5080>.
Notes:
This parameter is applicable only to the Gateway
application.
If not specified, the REGISTER request is sent to the
primary Proxy server.
When a port number is specified, DNS NAPTR/SRV queries
aren't performed, even if the parameter DNSQueryType is
set to 1 or 2.