Changing Set Values And Current Values Of T, C And D - Mitsubishi Electric F930GOT-BWD Operation Manual

Got-f900 series graphic operation terminals melsec-got
Table of Contents

Advertisement

Graphic Operation Terminal GOT-F900
10.4.2

Changing set values and current values of T, C and D

Set values and current values of word devices (T, C, D, V or Z) in the PLC can be changed.
u u u u Basic operation
T/C/D monitor
display
Read the values
using the procedure
described in the
previous paragraph.
*1 When the SET key is pressed, the cursor is moved to a current or set value
and the numeric input keyboard is displayed at the bottom of the screen.
Example:
5
0
n n n n Important point
1) Changing set values of T or C and file registers
They can be changed when RAM is used as the memory in the PLC.
They cannot be changed when an EPROM or EEPROM cassette is used.
,
SET
Move the
Change the
cursor to a
current value of
device to be
D, T or C. *1
changed.
D0
[1000]
Cursor
Numeric (decimal) input keyboard
6
7
8
9
1
2
3
4
0 to 9
Change
Enter the
Enter a
the set
minus (-)
numeric.
value of T
sign.
or C.
CLR
ENT
HPP Mode 10
ENT
Execute
change.
10-14