Graphic Operation Terminal GOT-F900
• Combination of touch keys
If a touch key on the alarm list is assigned with a key code from the table below, it will
perform its respective operation, also shown in the table.
Key codes used for the alarm list function
Key code
FFB0
FFB1
FFB2
FFB3
FFB8
FFBB
When a touch switch to which "FFB8" (detailed information display function) is assigned, the
alarm message (comment window) or the base screen is changed over, and the detailed
information is displayed.
To display the detailed information, "Detail Display Destination" in "Option" in "Alarm List
Display Setting" of the screen creation software should be set to "Comment Window" or
"Base Screen".
• When "Comment Window" is selected
When this button is pressed, the detailed
display window is closed.
DETAILS
• Changeover of base screen
The screen specified by "Detail Display No." in "Alarm List Display Setting"-"Option" of the
screen creation software is displayed.
Displays the cursor.
Deletes the cursor.
Moves the cursor upward.
Moves the cursor downward.
Displays the detailed information of the alarm selected by the cursor.
Resets the alarm in the line in which the cursor is located.
Creation of Display Screens (FX-PCS-DU/WIN-E) 18
Operation
• Move the cursor to the alarm message to be
displayed in detail and press the DETAIL key.
Then, the detailed display window is open as
shown on the left.
• The comment in the comment list specified by
"Detail Display No." in "Alarm List Display
Setting"-"Detail Display Setting" of the screen
creation software is displayed.