Mitsubishi Electric F930GOT-BWD Operation Manual page 309

Got-f900 series graphic operation terminals melsec-got
Table of Contents

Advertisement

Graphic Operation Terminal GOT-F900
Operation examples of "Bit SET" and "Bit RST"
When the SET key is pressed, Y1 is set. When the RST key is pressed, Y1 is reset.
- SwitchControl input: SET key, RST key
Controlled bit device: Y1 (set), Y1 (reset)
SET key (set)
RST key (reset)
Y1
n n n n Important point
1) Controlled bit device:
If "Operation" is set to "Momentary", the controlled bit device becomes OFF when the
display screen is changed over.
2) If two or more keys are pressed simultaneously:
If two or more switch functions are registered, and two keys are pressed, both functions will
be executed.
If three or more keys are pressed simultaneously, only the first two pressed will be effective.
3) If objects are assigned to one touch key:
If two or more switch functions are assigned or another object is assigned to one touch key,
the priority is given to a function/object registered first (while the screen is created).
4) If screens are overlaid:
If screens are overlaid using control devices or screen call function, the switch functions are
effective on all of the base screen and overlaying screens. If switches are overlaid, the
switch on the top screen is effective. Pay rigid attention so that switches are not overlaid.
Example
Base screen
A
In the switch areas A and B on the composed screen realized by overlay, each switch is
effective. However, if the area C is pressed, the switch B located on the top is effective.
ON
OFF
ON
OFF
ON
OFF
Overlaying screen
Creation of Display Screen (GT Designer) 20
B
Overlaying screen
A
B
20-35
C

Hide quick links: