Mitsubishi Electric F930GOT-BWD Operation Manual page 121

Got-f900 series graphic operation terminals melsec-got
Table of Contents

Advertisement

Graphic Operation Terminal GOT-F900
Operation example
Monitor the ON/OFF status of inputs X000 and X001, and the current value and set value of
timer T3
Display screen 1
X 000
T
3
RST( )
Display screen 2
SW1
TIM
RST( )
The ON/OFF status of each monitored
device is indicated as follows.
ON status
OFF status
n n n n Important point
1) Monitor function when timers and counters are indirectly specified
X 001
CUR
[ 1234]
SET
[ 2345]
SW2
CUR
[ 1234]
SET
[ 2345]
If a data register is used for the set value of a timer/counter as
T10
shown in the program on the left, the contents of the data register
D5
are used when monitoring is performed.
C10
D6
When the set value is changed (as described on the next page),
the contents of the data register is overwritten.
HPP MODE
DEVICE MONITOR
screen is
displayed.
Select "DEVICE
MONITOR" on the
Paragraph 7.3
screen.
0
ENT
Select
Display "X0"
Display "X1" on
"X0".
on the screen.
the screen.
DEVICE
T
3
Enter a device
Select
symbol "T".
"T3".
When a comment has been entered to a device,
COMMENT
looth are displayed together.
Display the
When a comment has not been entered to a device,
screen 2.
the device is displayed with the symbol.
This comment display function is valid only when
comments have been created using the screen
creation software FX-PCS-DU/WIN-E.
HPP Mode 10
DEVICE
X
Enter a device
symbol "X".
ENT
Display
screen 1.
10-13