20.5.7

Part display function

The "Part Display" object displays figures in accordance with the ON/OFF status of bit devices
in the PLC and the current value of word devices in the PLC.
By using the part display function, figures created by the user can be displayed.
u u u u Contents of setting
1) Specification method
Bit device
Word device
2) Contents of display
Bit device:
Part No. of a figure to be displayed while a specified bit device is ON
Part No. of a figure to be displayed while a specified bit device is OFF
Word device:
Part No. of a figure which is equivalent to the current value of a specified word device
Creation of displayed figure:
Figures can be created and registered using the screen creation software.
Figures can be stored in BMP files, etc.
u u u u Display example
Part Display
Device
Part No. for ON status
Part No. for OFF status
• The specified part is displayed in the same size as registered in the screen creation
software.
M0
Part No. 20
50 W × 50 H dots
20
30
Part No. 30
100 W × 100 H dots
Creation of Display Screen (GT Designer) 20
Display
start point
When M0
becomes ON,
part No. 20 is
displayed.
Display
start point
When M0
becomes
ON, part No.
20 is
displayed.
Display screen