Specifications; General Specifications - Mitsubishi Electric F930GOT-BWD Operation Manual

Got-f900 series graphic operation terminals melsec-got
Table of Contents

Advertisement

Graphic Operation Terminal GOT-F900
2.

Specifications

For the power supply specifications, refer to "GOT-F900 SERIES HARDWARE MANUAL".
2.1

General specifications

Item
Temperature
Humidity
Vibration
resistance
Shock
resistance
Noise
resistance
Withstand
voltage
Insulation
resistance
Grounding
Working
atmosphere
Protective
structure
Use: 0 to 50°C (32 to 122°F) (0 to 40°C when using an extension interface or for handy
GOT)
Storage: -20 to 60°C (-4 to 140°F)
In the case of F940WGOT, ambient temperature should be 0 to 50°C for vertical
mounting; 0 to 40°C for horizontal mounting.
35 to 85%RH (non-condensing) (35 to 80%RH for F930GOT)
With
intermittent
Conforms to
vibration
IEC 1131-2
With
continuous
vibration
Conforms to IEC 1131-2 (147m/s
1,000Vp-p, 1µs, 30 to 100Hz, tested by noise simulator.
500V AC for 1 min
5MΩ or more at 500V DC
Class D (100Ω or less)
No corrosive gas and no significant dust
Equivalent to IP65F (Handy GOT: IP54)
Specifications
Frequency
Acceleration
10 to 57Hz
57 to 150Hz
9.8m/s
10 to 57Hz
57 to 150Hz
4.9m/s
2
, 3 times in each direction X, Y and Z)
Tested between power terminals and ground
Specifications 2
Amplitude
0.075mm
10 times in each
of X, Y and Z
2
directions
0.035mm
(for 80 minutes)
2
2-1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents