End Cond - Mitsubishi Electric F930GOT-BWD Operation Manual

Got-f900 series graphic operation terminals melsec-got
Table of Contents

Advertisement

Graphic Operation Terminal GOT-F900
11.2.3

END COND.

Set the timing at which sampling finishes. When the end condition is satisfied, sampling
finishes.
• Sampling end by occurrence
Sampling is finished after the specified number of times (2,000 times maximum).
• Sampling end by time
Sampling is continued until the specified time. However, when data on more than 2,000
times has been acquired, the data acquired so far is deleted, oldest first and new data is
saved (that is, the sampling data is shifted).
• Sampling end by trigger
Sampling is finished when the specified device No. becomes ON or OFF. However, when
data on more than 2,000 times has been acquired, the data acquired so far is deleted oldest
first and new data is saved.
u u u u Basic operation
SET CONDITION
screen is displayed.
SET
1)
Display the
ten-key pad.
SET
2)
Display the
ten-key pad.
3)
SET
Display the
device input
keyboard.
END COND.
Select "END
COND".
0 to 9
ENT
Enter the number of
times.
0 to 9
ENT
Set date, hour, minute and
second.Set date, hour,
minute and second.
Device symbol
Select a bit device from X, Y, M, S, T or C.
They are changed over alternately.
NUMBER
TIME
Select "NUMBER".
Select "TIME".
Screen 1 is
Screen 2 is
displayed.
displayed.
1) Sampling end by
2) Sampling start
occurence
by time
Device No.
ENT
Execute
the input.
Sampling Mode 11
DEVICE
Select "DEVICE".
Screen 3 is
displayed.
3) Sampling end
by trigger
OFF -> ON
Change over
à
"OFF
ON" and
à
"ON
OFF".
11-7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents