Graphic Operation Terminal GOT-F900
2) Level device setting function
By making setting as shown below, the current security level (0 to 15) set on the GOT can
be checked through the PLC.
• Setting for GT-Designer (SW5D5C-GOTR-PACK)
1) The window shown in the previous page can be displayed by using "Common" →
"Password".
2) When the "Level device" item is checked, device setting for security level can be made.
By checking the current set value of the device here, you can know the current security
level.
3) Security level setting function for system screen
Previously the security level of the system screens (No.1000 to 1030) was fixed at 15. Now
it is possible to set the security level of the system screens by make setting as shown below.
• Setting for GT-Designer (SW5D5C-GOTR-PACK)
1) The window shown below can be displayed by using "Common" → "Auxiliary setting" →
"Screen".
2) When "Use sequrity level of utility screen" at the bottom of the window is checked, it
becomes possible to set the "Utility" tag.
3) When "Utility" is selected, the list of the system screens are displayed. Select the
number of the screen whose security level you want to change and set the security level
by mouse double-clicking or using the "Edit" button.
* If this setting is not performed or the screen data are all cleared, the security level of the
system screens is initialized to 15.
Check it.