Mitsubishi Electric F930GOT-BWD Operation Manual page 286

Got-f900 series graphic operation terminals melsec-got
Table of Contents

Advertisement

Graphic Operation Terminal GOT-F900
3) Shift
• When the number of digits to be displayed is smaller than the specified total number of
digits, the numeric is automatically shifted to the right, the center or the left in accordance
with the setting.
Example: When the specified total number of digits is set to 9 and the displayed numeric is
a 3-digit value
Right
:
Center
:
Left
:
4) Gain 1, gain 2 and offset
The value obtained by the calculation "(Monitor value x Gain 1 / Gain 2) + Offset" is
displayed.
Example: When the monitor value is 1000 (current value of D100), the gain 1 is set to 10,
the gain 2 is set to 2 and the offset is set to 3
(1000 × 10 ÷ 2) + 3 = "5003" is displayed.
u u u u Display example
"Text" object
n n n n Important point
• Display of numerics for timers and counters:
When a device whose numeric is to be displayed is set to a timer or counter, its current
value is displayed.
To display the set value of a timer/counter, specify indirectly the set value of the timer/
counter to be displayed as shown below, then display the value of the specified data
register.
Start point
1
2
3
1
2
3
HEATING TIME
LINE 1
LINE 2
When T0 is specified as a device whose
T0
numeric is to be displayed, the current value
D10
of T0 is displayed.
When D10 is specified as a device whose
numeric is to be displayed, the set value of
T0 is displayed.
Creation of Display Screen (GT Designer) 20
1
2
3
89.6 s
126.3 s
"Number" object
20-12