3
In the <Target Device> group, select the control panel
to handle the GPI input.
Notes
The SCU2 setting is disabled.
The action set in the next step 4 is executed for the
switcher and DME controlled by the selected control
panel.
4
In the list on the right, select the action.
5
Press [Action Set].
Selectable actions for various trigger types
• When the trigger type is other than "Level"
(The x in M/E-x is the M/E bank number, the x in DSKx
is the DSK number, and the x in Keyx is the key
number.)
M/E-x Cut, M/E-x Auto Trans, P/P Cut, PP Auto Trans,
M/E-x Keyx Cut, M/E-x Keyx Auto Trans, P/P DSKx
Cut, P/P DSKx Auto Trans, FTB Auto Trans, FTB Cut,
Master SS ? Recall, SS ? Recall, M/E-x Keyx SS ?
Recall, P/P DSKx SS ? Recall, Master Effect ? Recall,
Effect ? Recall, Effect ? Recall & Run, KF Run, KF
Stop, KF Rewind, FM Src1 Field Freeze, FM Src1
Frame Freeze, FM Src1 Freeze Off, FM Src2 Field
Freeze, FM Src2 Frame Freeze, FM Src2 Freeze Off, FM
Src1 Clip Record, FM Src1 Clip Stop, FM Src2 Clip
Record, FM Src2 Clip Stop, FM1 to FM8 Clip Cueup,
FM1 to FM8 Clip Play, FM1 to FM8 Clip Stop, Shotbox
? Recall, Macro Take, Macro ? Recall, No Action
• When the trigger type is "Rising Edge" or "Falling
Edge"
Aux ? O'ride Src ??
• When the trigger type is "Level"
(The x in M/E-x is the M/E number.)
System Format, System Aspect, M/E-x Aspect, P/P
Aspect, DME Ch1 Aspect, DME Ch2 Aspect, Level
Enable, No Action
For details about "Level Enable," see "Notes" in
"Making Control Panel GPI Input Settings"
(1 p.
337).
Notes
• As for "Aux ? O'ride Src ??," when "Rising Edge" is
selected, for example, on the rising edge the set AUX
bus input is used, and on the falling edge, the original
state of the cross-point is restored. If the GPI trigger is
applied repeatedly at short intervals (0.5 second or less),
the cross-point switching may not be carried out
correctly. In this case, apply the GPI trigger again.
• If "System Format" is selected for "Action" when the
format converter is used on the switcher, you can set the
conversion format of the format converter for "FC Input
1-4," "FC Input 5-8" and "FC Output 1-2."
Carrying out level settings
To set the low level and high level, first set the trigger type
to "Level," then use the following procedure.
1
In the Engineering Setup >DCU >GPI Input Assign
menu (7352), select the action to be set and press [H/L
Set].
The H/L Set menu (7352.1) appears.
2
Select the setting.
3
To apply the selection made in step 2 when the input
is the GPI high level, press [H Set]. To apply the
selection the input is low, press [L Set].
To set the level for the format converter
1
Set "System Format" for "Action" using the same
"Making DCU GPI Input
operation in step 4 in
Settings" (1 p.
366).
The format converter list appears.
2
Select the format converter that you want to set from
3
In the <FC Input/Output> group, press [H Set] or [L
Set] to set the high level or low level, respectively.

Parallel Output Settings

For the DCU parallel output ports, after carrying out tally
settings in the Engineering Setup >Router/Tally >Tally
Enable menu (7364), you can assign GPI outputs to output
ports that are still unused.
Assigning a GPI Output Port
1
In the Engineering Setup >DCU >Output Config menu
(7353), select what the setting applies to (DCU1 or
DCU2) from the <DCU Select> group.
2
In the <Parallel Output Assign> group, press [GPI
Output].
3
Select the output port and GPI output number.
Notes
When the MKS-2700 is connected, make the
following settings.
• Parallel Output Slot: 2