Assigning A Parallel Output Port - Sony MVS-6520 User Manual

Multi format switcher system with icp-series control panel
Hide thumbs Also See for MVS-6520:
Table of Contents

Advertisement

Selectable actions for various trigger types
• When the trigger type is other than "Status"
(The x in M/E-x is the M/E bank number, the x in DSKx
is the DSK number, and the x in Keyx is the key
number.)
When Source is M/E-x: Keyx SS ? Recall, No Action
When Source is P/P: DSKx SS ? Recall, No Action
When Source is Common: KF Run, No Action
• When the trigger type is "Status"
(The x in M/E-x is the M/E bank number, the x in DSKx
is the DSK number, and the x in Keyx is the key
number.)
When Source is M/E-x: Keyx SS ? Recall, Keyx On, No
Action
When Source is P/P: DSKx SS ? Recall, DSKx On, No
Action
When Source is Common: Error Make, Error Break,
Keep Break, Keep Make, PREFS1, PREFS2,
PREFS3, PREFS4, PREFS5, PREFS6, PREFS7,
PREFS8, PREFS9, PREFS10, PREFS11, PREFS12,
PREFS13, PREFS14, PREFS15, PREFS16, Device
Recording, No Action
Test firing the trigger
Press [Test Fire].
This outputs a trigger from the selected output port. This is
no output when the trigger type is "Status."

Assigning a Parallel Output Port

This sets the Tally/GPI OUTPUT port on the rear panel of
the switcher.
1
Open the Engineering Setup >Panel >Device Interface
>Tally/GPI Output Config menu (7325.12).
2
Select the setting.
3
In the <Parallel Output Assign> group, select one of
the following.
Tally Output: Assigns a tally output.
Switcher: Assigns a switcher GPI output.
Panel: Assigns a control panel GPI output.
4
Select the output you want to assign from the list on
the right.
5
Press [Action Set].
Setting the Control Mode for P-Bus
Devices
This sets the control mode for external P-Bus (Peripheral
II protocol) devices.
In the <P-Bus Control> group of the Engineering Setup
>Panel >Device Interface menu (7325), select the mode.
Trigger: When a predetermined button is pressed, the
Timeline: Controls the external device as a keyframe
effect controlled by the center control panel.
Associating a Port with a Device
Selection Button
1
Open the Engineering Setup >Panel >Device Interface
>Device Assign menu (7325.4).
2
Select the port to set.
3
In the <Assign> group, press one of the [DEV1] to
[DEV12] buttons.
Notes
• It is not possible to assign more than one device
selection button to the same port. The later assigned
device selection button takes priority, and the
previous selection is invalidated.
• If P-Bus/Mixer ESAM-II is assigned to a serial port,
it is not possible to assign a device selection button
to that port.
4
Repeat steps 2 and 3 as required to make assignments
to other ports.
Sharing disk recorder/Extended VTR file
lists
You can share files between devices connected to ports on
the same disk recorder/Extended VTR.
1
Select the port to set.
2
Select the device selection button for sharing the file
list.
3
Press [Same File List Set].