Releasing The Assignment Of A Gpi Output Port - Sony MVS-6520 User Manual

Multi format switcher system with icp-series control panel
Hide thumbs Also See for MVS-6520:
Table of Contents

Advertisement

• Parallel Output Port: 1 to 36
4
Press [GPI Output Set].
Releasing the Assignment of a GPI
Output Port
1
In the Engineering Setup >DCU >Output Config menu
(7353), select what the setting applies to (DCU1 or
DCU2) from the <DCU Select> group.
2
In the <Parallel Output Assign> group, if [GPI Output]
is on, press it to turn it off.
3
Select the slot and port to which the setting applies.
No.
Parameter
1
From Slot
2
From Port
3
To Slot
4
To Port
4
In the <Parallel Output Assign> group, press [No
Assign].
GPI Output Settings
This sets the trigger type and so on for each GPI output.
Making DCU GPI Output Settings
1
In the Engineering Setup >DCU >GPI Output Assign
menu (7354), select what the setting applies to.
2
In the <Trigger Type> group, select the trigger type.
(Rising Edge): The trigger causes the relay
contacts to be open-circuit or drives the output
high, and holds this state for the specified pulse
width.
(Falling Edge): The trigger causes the relay
contacts to be shorted or drives the output low, and
holds this state for the specified pulse width.
(Any Edge): Each time the trigger occurs, the
relay contacts are alternately closed or opened, or
the output is switched between high and low.
Status: Depending on the status, the relay contacts are
closed or opened, or the output is switched
between high and low.
368
GPI Output Settings
Adjustment
First port slot
First port number
Last port slot
Last port number
No Operation: The trigger has no effect on the relay
state or output level.
3
Select the pulse width and timing to be set.
No.
Parameter
Adjustment
3
Pulse Width Pulse width
Output timing
4
Timing
a) 1: Field 1, 2: Field 2, 3: Any
When "
" is selected as the trigger polarity, there is
no Pulse Width setting. When "Status" is selected,
there is no Pulse Width or Timing setting.
4
In the <Source Device> group, select the control panel
or DCU to handle the GPI output.
Notes
The SCU2 setting is disabled.
When the action set in the following step 5 is carried
out on the control panel selected here, this causes a
GPI output. It is also possible to output error
information.
When the DCU is selected, you can output error
information by means of the action set in step 5.
5
In the list on the right, select the action.
6
Press [Action Set] to confirm the action selection.
Selectable actions for various trigger types
• When the trigger type is other than "Status"
(The x in M/E-x is the M/E bank number, the x in DSKx
is the DSK number, and the x in Keyx is the key
number.)
When Source Device is SCU: M/E-x Keyx SS ? Recall,
P/P DSKx SS ? Recall, No Action
When Source Device is DCU: No Action
• When the trigger type is "Status"
(The x in M/E-x is the M/E bank number, the x in DSKx
is the DSK number, and the x in Keyx is the key
number.)
When Source Device is SCU: M/E-x Keyx SS ? Recall,
P/P DSKx SS ? Recall, M/E-x Keyx On, P/P DSKx
On, Error Make, Error Break, Keep Make, Keep
Break, Device Recording, No Action
When Source Device is DCU: Error Make, Error Break,
No Action
Test firing the trigger
Press [Test Fire].
This outputs a trigger from the selected output port. This is
no output when the trigger type is "Status."
a)