Sony MVS-6520 User Manual page 194

Multi format switcher system with icp-series control panel
Hide thumbs Also See for MVS-6520:
Table of Contents

Advertisement

No.
Parameter
a)
3
Offset A
b)
Speed A
4
5
Amp R
a) Set when Lock is on.
b) Set when Lock is off.
When Both mode is selected
Parameter group [1/2]
No.
Parameter
1
Amp R
2
Freq R
a)
Offset R
3
b)
Speed R
4
Parameter group [2/2]
No.
Parameter
1
Amp A
2
Freq A
a)
Offset A
3
b)
Speed A
4
a) Set when Lock is on.
b) Set when Lock is off.
When Shape mode is selected
Parameter group [1/2]
No.
Parameter
1
Amp R
2
Freq R
a)
Offset R
3
b)
Speed R
4
5
Shape
Parameter group [2/2]
No.
Parameter
1
Aspect
2
Angle
a) Set when Lock is on.
b) Set when Lock is off.
194
Applying Special Effects (Nonlinear Effect Settings)
Adjustment
Direction along periphery in
which to offset ripple phase and
amount of movement
Ripple direction along periphery
and speed
Ripple amplitude along radius
Adjustment
Ripple amplitude along radius
Ripple frequency along radius
Direction along radius in which to
offset ripple phase and amount of
movement
Ripple direction along radius and
speed
Adjustment
Ripple amplitude along periphery
Ripple frequency along periphery
Direction along periphery in
which to offset ripple phase and
amount of movement
Ripple direction along periphery
and speed
Adjustment
Ripple amplitude
Ripple frequency
Direction in which to offset ripple
phase and amount of movement
Ripple direction and speed
Ripple shape
Adjustment
Ripple aspect ratio
Ripple angle
To limit the direction in which modulation is
applied
By pressing [Plus Only], turning it on, you can limit the
direction in which modulation is applied (the direction in
which the image expands) to the plus direction only.
To set the ripple center point
1
Press [Position], turning it on.
2
Set the following parameters, depending on the
selected modulation mode.
When Shape mode is selected
No.
Parameter
Adjustment
1
H
Ripple center point in horizontal
direction
2
V
Ripple center point in vertical
direction
When mode other than Shape is selected
No.
Parameter
Adjustment
1
H
Ripple center point in horizontal
direction
2
V
Ripple center point in vertical
direction
To limit the ripple range
1
Press [Range], turning it on.
2
Set the following parameters.
When Radial or Shape mode is selected
No.
Parameter
Adjustment
1
Size R
Amount of ripple modulation
along radius
2
Offset R
Center of modulation range along
radius
When Angular mode is selected
No.
Parameter
Adjustment
1
Size A
Amount of ripple modulation
along periphery
2
Offset A
Center of modulation range along
periphery
When Both mode is selected
No.
Parameter
Adjustment
1
Size R
Amount of ripple modulation
along radius
2
Offset R
Center of modulation range along
radius
3
Size A
Amount of ripple modulation
along periphery

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents