Sony MVS-6520 User Manual page 407

Multi format switcher system with icp-series control panel
Hide thumbs Also See for MVS-6520:
Table of Contents

Advertisement

Menu
Number
Path
Engineering Setup >Panel >Config
7321.18
>Util Bus/Key Inhibit
Engineering Setup >Panel >Config
7321.19
>Menu Panel
7322
Engineering Setup >Panel >Xpt
Assign
7322.5
Engineering Setup >Panel >Xpt
Assign >Main, V/K Pair Assign
7322.6
Engineering Setup >Panel >Xpt
Assign >Src Name/Src Color
7325.1
Engineering Setup >Panel >Device
Interface >GPI Input
7325.3
Engineering Setup >Panel >Device
Interface >GPI Output
7326.11
Engineering Setup >Panel
>Operation >Custom Button >Next
Trans All
Engineering Setup >Panel
7326.13
>Operation >Key/AUX/Function
Assign
7331
Engineering Setup >Switcher >Config M/E-2 settings
Engineering Setup >Switcher >Config
7331.1
>M/E Output Assign
Engineering Setup >Switcher >Config
7331.2
>PGM Config
7331.3
Engineering Setup >Switcher >Config
>K-PVW Config
Engineering Setup >Switcher >Config
7331.6
>DME Config
7332
Engineering Setup >Switcher >Input
7332.1
Engineering Setup >Switcher >Input
>CCR
7332.3
Engineering Setup >Switcher >Input
>FC Input Select
7333.1
Engineering Setup >Switcher
>Output >Output Assign
Engineering Setup >Switcher
7333.2
>Output >Video Clip
Engineering Setup >Switcher
7333.3
>Output >V Blank/Through
Engineering Setup >Switcher
7333.4
>Output >Safe Title
Disabled operation/setting
• M/E-2 settings
• [Key5] to [Key8] selection
M/E-2 selection
Setting of items related to M/E-2
Primary 33 to 48, M/E-2 Out1 to M/E-2 Out4 selection
Primary 33 to 48, M/E-2 Out1 to M/E-2 Out4 settings
• Primary 33 to 48 selection when Action is set to Aux Bus Xpt Override
• [M/E-2] selection
• Selection of the following items when Trigger Type is not set to Level in
[M/E-1] (x=5 to 8): Keyx Cut, Keyx Auto Trans, Keyx SS ? Recall
• Selection of the following items when Trigger Type is not set to Level in
[P/P] (x=5 to 8): DSKx Cut, DSKx Auto Trans, DSKx SS ? Recall
• [M/E-2] selection
• Selection of the following items when Trigger Type is not set to Status
in [M/E-1] (x=5 to 8): Keyx SS ? Recall
• Selection of the following items when Trigger Type is set to Status in
[M/E-1] (x=5 to 8): Keyx SS ? Recall, Keyx On
• Selection of the following items when Trigger Type is not set to Status
in [P/P] (x=5 to 8): DSKx SS ? Recall
• Selection of the following items when Trigger Type is set to Status in
[P/P] (x=5 to 8): DSKx SS ? Recall, DSKx On
Key5 to 8 selection
• M/E-2 settings
• Key5 to 8 selection
M/E-2 settings
• M/E-2 settings
• [Key5] to [Key8] selection
• M/E-2 settings
• [Key5] to [Key8] selection
M/E-2 settings
Primary 33 to 48 settings
Primary 33 to 48 settings
Primary 33 to 48 selection
• Output 17 to 32 settings
• M/E-2 Out1 to M/E-2 Out4 selection
Output 17 to 32 settings
Output 17 to 32 settings
Output 17 to 32 settings
Menus of Disabled Operations and Settings
407

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents