12.1.4 PBX Configuration—[4-1-4] Extension—Wired Extension—Flexible Button
Value Range
Table 1–Table 32 or Table 1–Table 128
Note
The maximum number of time tables (1 per tenant) depends on the System Capacity Selection setting
made when the Easy Setup Wizard was run for the PBX. If the System Resource Type was selected, the
maximum number of tenants (and therefore, time tables) is 128. If the Standard Type or IP-Extension
Type was selected, the maximum number of tenants is 32. For details, refer to "5.4.1 Easy Setup
Wizard" in the Installation Manual.
Maintenance Console Location
12.1.4 PBX Configuration—[4-1-4] Extension—Wired Extension—Flexible Button
Feature Guide References
5.1.4 Time Service
Optional Parameter (Ringing Tone Type Number) (for Loop CO, Single CO,
Group CO, ICD Group, SDN)
Specifies the ring tone type.
Value Range
IP-PT (except KX-NT265/KX-NT321): 1–30
KX-NT265/KX-NT321: 1–8 (Even if ring tone 9–30 is selected, ring tone 1 is heard.)
S-PS: Not available.
Other telephones: 1–8 (Even if ring tone 9–30 is selected, ring tone 2 is heard.)
Maintenance Console Location
12.1.4 PBX Configuration—[4-1-4] Extension—Wired Extension—Flexible Button
Optional Parameter (Ringing Tone Type Number) (for Call Park)
Specifies the number of the parking zone a call is to be parked in when a Call Park button with
Selection (for Call Park) on this screen set to Specific is pressed.
Value Range
Park 00–Park 99
Maintenance Console Location
12.1.4 PBX Configuration—[4-1-4] Extension—Wired Extension—Flexible Button
Feature Guide References
2.13.2 Call Park