11.5.1 PBX Configuration—[3-5-1] Group—Incoming Call Distribution Group—Group Settings
11.5 PBX Configuration—[3-5] Group—Incoming
Call Distribution Group
11.5.1 PBX Configuration—[3-5-1] Group—Incoming Call
Distribution Group—Group Settings
Extensions can be assigned as members of an incoming call distribution group. Calls to an incoming call
distribution group are distributed to its member extensions as programmed. A maximum of 128 incoming call
distribution groups can be programmed.
To set the Call Forwarding (FWD) settings of ICD groups easily, click Group FWD. To assign extensions to
ICD groups and change extension settings, click Member List.
For more information on ICD Groups, see "2.2.2.1 Incoming Call Distribution Group Features—SUMMARY"
in the Feature Guide.
Main
Floating Extension Number
Specifies the floating extension number of the incoming call distribution group.
Value Range
Max. 5 digits (consisting of 0–9)
Maintenance Console Location
11.5.1 PBX Configuration—[3-5-1] Group—Incoming Call Distribution Group—Group Settings
Group Name
Specifies the name of the incoming call distribution group.
Value Range
Max. 20 characters
Maintenance Console Location
11.5.1 PBX Configuration—[3-5-1] Group—Incoming Call Distribution Group—Group Settings
Distribution Method
Selects the method for distributing calls to idle extensions of the incoming call distribution group.
Value Range
Ring, UCD, Priority Hunting
Maintenance Console Location
11.5.1 PBX Configuration—[3-5-1] Group—Incoming Call Distribution Group—Group Settings