4 . 3
D I G I T A L OPERATOR MENU TREES
A . Q u i c k - s t a r t A c c e s s L e v e l
The flowchart tree below illustrates the process of accessing drive parameters when the
Access Level is set to Quick Start ( A 1 - 0 1 = 2).
Operation
MENU
Drive operation is enabled.
Drive status is displayed.
Initialize
A
( Initialize )
LCD language display is selected.
Parameter access levels, control
method selection and initialize
passwords are set.
Programming
( Programming )
Parameters are set/read. Items to be
set/read vary depending on the access
level setting.
Auto-tuning
( Auto-tuning )
Motor parameters are
automatically set by entering
tuning data (motor nameplate
values) when using Open
Loop or Flux Vector control
method ( A1-02 = 2 or 3).
Modified Constants
( Modified Parameters )
Only parameters that have been
changed from the factory settings are
set/read.
NOTES
(1)
A Function is a "sub-menu"
containing many parameters.
Use the DATA/ENTER key to
access these parameters.
(2)
This parameter is user
selectable according to the
setting of o1-01 .
(3)
Not available for all Control
Methods.
DATA
ENTER
Use the
and
keys to
scroll through the Functions and Parameters.
DATA
ENTER
DATA
ENTER
4-4
Display
Frequency Reference
U1-01
U1-02
Output Frequency
U1-03
Output Current
Output Voltage (2)
U1-06
Fault Trace
U2
U3
Fault History
U1
Monitor
A1-00
Select Language
Access Level
A1-01
Control Method
A1-02
Init Parameters
A1-03
A1-04
Enter Password
b1-01
Reference Source
b1-02
Run Source
b1-03
Stopping Method
Accel Time 1
C1-01
C1-02
Decel Time 1
d1-01
Reference 1
d1-02
Reference 2
Reference 3
d1-03
Reference 4
d1-04
d1-09
Jog Reference
E1-01
Input Voltage
E1-02
Motor Selection
V/F Selection (3)
E1-03
E1-04
Max Frequency
E1-05
Max Voltage
E1-06
Base Frequency
Mid Frequency A (3)
E1-07
Mid Voltage A (3)
E1-08
E1-09
Min Frequency
Min Voltage (3)
E1-10
Base Voltage (3)
E1-13
Motor Rated FLA
E2-01
Motor Rated Slip (3)
E2-02
No-Load Current (3)
E2-03
Number of Poles (3)

E2-04

Function (1) or
Parameter
Parameter
Parameter
Parameter
Parameter
Function
Function
Function
Parameter
Parameter
Parameter
Parameter
Parameter
Parameter
Parameter
Parameter
Parameter
Parameter
Parameter
Parameter
Parameter
Parameter
Parameter
Parameter
Parameter
Parameter
Parameter
Parameter
Parameter
Parameter
Parameter
Parameter
Parameter
Parameter
Parameter
Parameter
Parameter
Parameter